Product Name | Voltage | Accuracy class | 1) Specifications | 2) Function Option | Type |
DTSD607, | MQ | 1 | 6M4 | H | B |
DTSD607 DSSD607 |
MQ: 220/380V WY: 57.7/100V Y: 100V Q: 380V |
0P5: class 0.5S 2: Class 2 |
6M4: 1.5 (6)A ... 100M3: 30 (100)A |
H: Connect via VT/CT Default: Connect Directly |
B: Simple Default: Compact |
Name | Model | Type | Reference Voltage (V) | Accuracy class | Basic Current (Max. Current) (A) |
Three-phase four-wire Electronic Multi-functional Energy Meter | DTSD607 | Common |
3×220/380
|
0.5S, 1 | 1(2), 1.5(6), 3(6), 5(20), 5(30), 5(60), 10(40), 10(60), 10(100), 15(60), 20(80), 30(100) |
3×57.7/100 | 1(2), 1.5(6) | ||||
Three-phase three-wire Electronic Multi-functional Energy Meter | DSSD607 | 3×380 | 1(2), 1.5(6) | ||
3×100 | |||||
Three-phase four-wire Electronic Multi-functional Energy Meter | DTSD607 | Compact | 3×220/380 | 1, 2 | 1(2), 1.5(6), 3(6), 5(20), 5(30), 5(60), 10(40), 10(60), 10(100), 15(60), 20(80), 30(100) |
3×57.7/100 | 1(2), 1.5(6) | ||||
Three-phase three-wire Electronic Multi-functional Energy Meter | DSSD607 | 3×380 | 1(2), 1.5(6) | ||
3×100 |
Note: 1) “M” in the specification code represents multiple of current.
2) The function of connection via VT/CT is only available for 1.5(6)A & 3(6)A meters with the rated secondary current of the transformer is 5A.
Order Information:
The Ordering code for three-phase four-wire electronic multi-tariff energy meter connected via CT/VT (220V, Class 1 & 1.5 (6)A) is DTSF607MQ16M4H.
■Model DT (S) D607 Three-phase Electronic Multi-functional Energy Meter consists of the measuring unit and the data processing unit.
■The design and structure of the energy meter ensure no danger when used under rated conditions.Function Characteristics
■ Metering: Total Active & Reactive Energy, Total Four-quadrant Reactive Energy, Forward & Reversed Active Energy at All Tariffs, Forward & Reversed Reactive Demand at All Tariffs, Total Current Forward & Reversed Reactive Energy, and Max. Demand at all Tariffs & Max.Demand Time
■ Output: Forward and backward Active Energy Output, Forward and backward Reactive Energy Output, Clock Output and Multi-functional Output.
■ Incident Recording: Loss of Voltage, Loss of Current, Voltage Eligibility Rate, Power Outage & Power Recovery, Programming, Demand Reset, Radio Time Synchronization, Forward Active Energy Freeze at the End of Time Period, Monthly Energy
■ Transient Parameter Measuring
■ Audible & Visual Alarm
■ Typical Day Load
Extended Functions
■ Monthly (Settlement of) Forward Active Energy Recording
■ Energy Freeze
■ Forward Active Energy Freeze at the End of Time Period
■ Power-off Meter Wake-up (Visual Wake-up is optional)
■ Independent Double 485 Communication Port
■ Current Detection in Case of No Voltage in Three Phases (Optional)
■ Meter Cover Open Recording (Optional)
■ Load Curve Recording (Optional)
■ Incident Packet Recording
Certificate | ZZ No. 00000321 |
International Standard | IEC62052-11 IEC62053-21 |
National Standard | GB/T 17215.301, GB/T 17215.322, GB/T 17215.323 |
Industry Standard | DL/T 645 |
Current Specifications A | 1 (2) , 1.5 (6) , 3 (6) , 5 (20) , 5 (30) , 5 (40) , 10 (40) , 5 (50) , 5 (60) , 10 (60) , 15 (60) , 20 (80) , 10 (100) , 30 (100) ) |
Reference Voltage V |
3×57.7/100, 3×220/380 (Three-phase Four-wire) 3×100, 3×380 (Three-phase Three-wire) |
Accuracy class |
Active 0.5S 1 Reactive 2 |
Power Consumption of Voltage Circuit | ≤ 2W and 5VA |
Power Consumption of Current Circuit | <1VA |
Data Backup Battery Voltage | 3.6VDC |
Power-off Meter Reading Battery Voltage | 6.0VDC |
Clock Accuracy (Daily Error) | ≤ 0.5S/d (23℃) |
Battery Capacity | ≥ 1200mAh |
Power-off Data Retention Time | ≥ 10 years (for new battery) |
Meter Range | 0~999999.99 kWh , 0~999999.99 kvarh |
Display | LCD |
Communication Baud Rate |
Port RS485①: 1200bps~9600bps, Port RS485②: 1200bps Infrared Port: 1200bps |
Communication Protocol | DL/T645-1997 Multifunctional Energy Meter Communication Protocol or local protocols |
Project Needs | The user can make a requirement for more functions if necessary when placing an order. |
Product Name | Current Specifications (A) |
Outline Dimensions Length×Width×Height (mm) |
Installation Dimensions Length×Width (mm) | Case Material |
DTSD607 DSSD607 |
1 (2) , 1.5 (6) , 3 (6) , 5 (20) , 5 (30) , 5 (40) , 10 (40) , 5 (50) , 5 (60) , 10 (60) , 15 (60) , 20 (80) , 10 (100) , 30 (100) 0.3 (1.2) , 1.5 (6)A |
293×175×80 |
150×215 150×215 |
ABS (flame-resistant) |