Product Name |
Input Method |
Outline Dimension |
Structure |
Display Method |
Combination Method of Electrical Parameter |
Range |
P□ |
□ | □ | □ | □ | □ | □ |
PD: PD2222Multi-function energy meter |
L: AC |
96: 96×96 72: 72×72 |
P: Metering display |
1: one-row of digital tube display 4: three-row of digital tube display Y: single-phase LCD display 3Y: three-phase LCD display |
E: Harmonic wave F: Multi-tariff |
*:*A (V) See referenced range table for details |
T: RS485 |
||||||
K: DO |
||||||
B: AO |
||||||
S: DO+RS485 |
||||||
D: AO+RS485 |
||||||
N: DO+AO+RS485 |
||||||
M: DI+AO+RS485 |
||||||
R: DI+DO+RS485 |
||||||
Note: 1) In structure, DI refers to digital input, indicating; DO refers to digital output, indicating; AO refers to Analog output; |
Input Method |
Type |
Structure |
AC |
Multi-function energy meter |
P: Metering display |
T: RS485 communication |
||
K: Digital output, indicating |
||
B: Analog output |
||
S: Digital output, indicating + RS485 communication |
||
D: Analog output + RS485 communication |
||
N: Digital output, indicating + Analog output + RS485 communication |
||
M: Digital input, indicating + Analog output + RS485 communication |
||
R: Digital input, indicating + Digital output, indicating + RS485 communication |
Ordering Information:
The ordering code for a three-phase multi-function energy meter with harmonic wave (input: AC, outline dimension: 96×96; structure: Digital output, indicating + Analog output + RS485 communication, three-phase LCD display) is PDL96N3YE.
Current Range |
Direct connection: 0.1A~5A |
Connect to 5A/5A~10kA/5A via CT with secondary current 5A |
|
Voltage Range |
Direct connection: 3V~600V |
Connect to 380V/100V~380kV/100V via VT with secondary voltage 100V |
Product Characteristics:
■ Direct viewing reading, long-life LED or HD LCD display;
■ High precision and good linearity to full range;
■ Stable working and reliable performance;
Standard & Certification
■Standards: Comply with: GB/T 22264.1~5-2008, GB/T 22264.7-2008, GB/T 22264.8-2009
■Certificates: License of manufacturing metering meters has been canceled (Proclamation No. 145 [2005])
Ambient Temperature |
Allowed working environment temp.: -10℃~+45℃ (Class 3K5 revised); |
Ambient Humidity |
≤93%RH |
Working Environment |
No fungus, insect, salt-spray, condensation, but slight dust is allowed. Normal type for meter's mechanical stress tolerance Altitude ≤2500m |
Input |
Technical Parameters |
Indicator |
|
Power grid |
Single-phase, three-phase |
||
Voltage |
Overvoltage |
Duration: 1.2 * Un transient: 2 * Un lasts for 1 sec. |
|
Current |
Overcurrent |
Duration: 1.2 * In transient: 10 * In lasts for 5 sec. |
|
Frequency |
45Hz~ 65Hz |
||
Functional module |
Electric energy pulse |
Two-circuit of electric energy pulse output |
|
Electric energy pulse constant |
Active 8000imp/kwh, reactive 8000imp/kvarh |
||
Digital input |
Passive dry-node optical coupling isolation |
||
Analog |
DC4~20mA (Load <600?) DC0~5/10V (Load >1k?) |
||
Alarm |
2-circuit passive relay output: 3A/30VDC, 3A/250VAC |
||
Alarm method: Amount of hysteresis can be set freely |
|||
Communication |
Method |
RS-485 |
|
Protocol |
MODBUS-RTU |
||
Baud rate |
2400, 4800, 9600 bps |
||
Display |
Display method |
LED display |
|
LCD display |
|||
Level |
Voltage, current, frequency, active power, reactive power, power factor |
Class 0.5 |
|
Active electric energy |
Class 0.5 or Class 1.0 |
||
Reactive electric energy |
Class 1.0 or Class 2.0 |
||
Auxiliary power supply (APS) |
Range |
AC/DC85V~265V |
|
Power consumption |
<4VA |
||
Safety |
Withstanding Voltage |
Input and auxiliary power supply |
>2kV50Hz/1min |
Input and output |
>2kV50Hz/1min |
||
Output and auxiliary power supply |
>2kV50Hz/1min |
||
Insulation resistance |
Auxiliary power supply, input, output Vs. meter case >100M? |
Model |
Outline Dimension |
Size of Installation hole |
Total Length |
Depth |
72 |
72×72 |
68×68 |
93 |
78 |
96 |
96×96 |
92×92 |
93 |
78 |
Arrangement Diagram of Connection Terminal for Model 96, 72;
Note: Wiring Diagram of Function Terminals (for reference only, see Wiring Diagram on the cover of energy meter for details)
1) Basic electricity metering + digital input + analog transformer output
2) Basic electricity metering + digital input + digital output
Wiring Diagram of Model 96, 72;